Feature
|
Description
|
Benefit
|
|
Fully
integrated and complete system
|
Complete
system includes suit, gloves, boots & respiratory system;
all individual components were configured & tested together
as a unified system
|
' Satisfies
operational need for safe, reliable & totally integrated
system
' Allows
total package procurement
|
|
Extensive
suit material testing
|
Suit
material tested against CW agents GA, GB, GD, HD, L & VX,
the 21 ASTM F 1001 chemicals, plus over 200 additional chemicals
|
' Suit material has proven chemical resistance
|
|
Suit
seam testing
|
Suit
seams tested against CW agents GB, HD, L & VX
|
' Suit
seams have proven chemical resistance
' Verifies
integrity of suit seams and suit fabrication quality
|
|
Tested
as an integrated system
|
Complete
system yielded a high overall protection factor when evaluated
with the U.S. Army man-in-simulant test (MIST) per TOP 10-2-022
and passed ASTM F 1359 shower spray test
|
' Verifies the safety & reliability of protective
ensemble
|
|
Suit
design
|
Totally-encapsulating
suit with panoramic view visor and expanded SCBA pod
|
' Ideal
for use with SCBAs that are not
CBRN hardened
' Distinctive
wrap-around visor provides large field of vision
' SCBA
pod fits any commercial
open-circuit or closed-circuit SCBA
|
|
Respiratory
protective system
|
Interspiro
60-minute open-circuit SCBA is recommended (any other commercial
open-circuit or closed-circuit SCBA can be used)
|
' Interspiro
system approved for use in CBRN environments
' Can
be matched with user’s current operational SCBA
' Non-CBRN
hardened SCBAs can be used
|
|
Suit
closure
|
Liquid-resistant
zipper assembly with 2-ply double splash flaps
|
' Assembly
resists vapor intrusion
' Liquid will not penetrate coverall closure assembly
' 2-ply splash flap design will not wick liquids
' No
taping needed
|
|
Exhaust
valve
|
Auer
valve with molded elastomer cover
|
' Exhaust
valve provides proper air exhaust to prevent excess internal
suit pressure (over inflation)
' Molded
elastomer covers resist inward leakage
|
|
Glove
system
|
24
mil neoprene/butyl gloves with Silver Shield/4H liners
|
' Neoprene/butyl
gloves have combined resistance to chemical warfare agents &
POLs
' Glove attachment assembly is vapor & liquid tight
' Gloves are easily changed out
' Glove
liners provide additional chemical resistance
|
|
Booties
|
Integral
booties and boot splash flaps incorporated into suit
|
' Provides
vapor & liquid tight attachment to suit
' Splash
flaps prevent liquid splash from entering boots
|
|
Boots
|
Boots
are seamless PVC alloy with steel safety toe, full steel mid-sole
& steel ladder shank; boots meet or exceed NFPA 1991 and
NFPA 1994 chemical permeation resistance requirements
|
' Provide
excellent impact protection
' Provide excellent cut & puncture resistance
' Provide